This edition brings together five developments concerning the next clinical decision in cancer imaging. We examine the complementary roles of CT and MRI in pancreatic cancer, PSMA-guided radiotherapy and the pre-biopsy BiPASS programme, reproducibility of PET/CT reporting in myeloma, and the requirements for emerging AI models. I offer my perspective on what these findings may mean for clinical practice and the direction of the field.
Meta-Analysis of Primary Detection and Staging Modalities in Pancreatic Cancer: Differentiating the Roles of CT, MRI, and EUS
What the evidence shows
A meta-analysis of 40 direct comparative studies demonstrated no statistically significant differences among computed tomography (CT), magnetic resonance imaging (MRI), and endoscopic ultrasonography (EUS) regarding the primary detection of pancreatic cancer. However, the diagnostic capabilities of these modalities diverged during disease staging: MRI demonstrated superior performance in imaging hepatic metastases, whereas CT outperformed other modalities in assessing vascular invasion and exhibited higher specificity in determining tumor resectability.
Potential impact
Incorporating liver MRI into the preoperative evaluation may add value when planning potentially curative surgery, supplementing standard CT staging.
Readiness for practice
Diagnostic teams can already consider using liver MRI in addition to CT when staging patients prior to resection. At the same time, a differentiated approach to vascular anatomy requires maintaining CT as the prioritized modality.
Limitations
The conclusions are constrained by heterogeneity among the studies included in the meta-analysis and a literature search cutoff date of July 2024, which must be taken into account when comparing with current diagnostic protocols.
PSMA-PET-Guided Radiotherapy in Prostate Cancer: Results of a Phase II Randomized Trial
What the evidence shows
In a phase II randomized trial analyzing 253 patients, the five-year failure-free survival was 66% in the PSMA-guided radiotherapy group versus 62% in the standard-of-care group; the study did not meet its primary endpoint. However, in the surrogate endpoint of biochemical progression-free survival, a benefit was observed in the investigational group (72% vs. 65%). Promising results were noted in high-risk subgroups and among post-prostatectomy patients.
Potential impact
Molecular imaging can change target selection and the personalization of radiotherapy. A changed treatment plan does not, by itself, demonstrate an improved clinical outcome. The biochemical progression signal is interesting, but the primary endpoint was not met; the findings need to be considered together rather than selecting only the favorable result.
Readiness for practice
This study alone does not justify a mandatory change in radiotherapy pathways for every patient. Phase III confirmation is important for the particular approach studied; this result should not be generalized to every use of PSMA PET in treatment planning.
Limitations
The primary endpoint was not met. Data regarding high-risk groups and post-prostatectomy patients were derived from exploratory analyses, and the study cohort exhibited marked clinical heterogeneity.
FDA Fast Track Designation for the BiPASS Diagnostic Program in Prostate Cancer
What the evidence shows
Telix reported that the U.S. Food and Drug Administration (FDA) granted Fast Track designation to the BiPASS program. The program evaluates the diagnostic combination of gallium-68 PSMA-PET and prostate MRI in the pre-biopsy setting. The phase III investigational program aims to comprehensively assess an imaging-first diagnostic pathway.
Potential impact
BiPASS is a step toward evaluating how molecular and anatomical imaging could work together at the earliest stages of the prostate cancer diagnostic pathway.
Readiness for practice
Fast Track designation facilitates regulatory interactions with FDA review staff, but it does not constitute regulatory market clearance for this indication, nor does it inherently prove the clinical benefit of the protocol.
Limitations
This is a company announcement about the programme’s regulatory status, not a publication of the final BiPASS results. It cannot quantify how many biopsies the programme would avoid or how patient outcomes would change.
Evaluation of the Reproducibility of the Structured IMPeTUs Protocol in Multiple Myeloma FDG-PET/CT
What the evidence shows
Three nuclear medicine physicians from different institutions performed repeat readings over a 10-week interval, reviewing 50 FDG PET/CT examinations twice with the IMPeTUs structured reporting system. Agreement was strongest for grouping lytic lesions and assigning the Deauville score to the most metabolically active bone lesion. Fractures and extramedullary disease showed lower agreement.
Potential impact
For departments introducing structured reporting, these results highlight where clearer definitions and focused reader training may be needed.
Readiness for practice
The IMPeTUs protocol may be considered a structured reporting tool; however, implementation requires standardized staff training. The study evaluates solely interobserver reproducibility, not diagnostic accuracy or impact on clinical patient outcomes.
Limitations
Small sample size (50 scans) and a limited pool of expert readers (three specialists). The publication is accepted for print and made available ahead of the final version of the article.
The MOSAIC-PET Conceptual Framework for Multimodal Artificial Intelligence Models in PET/CT
What the evidence shows
A narrative review examined the transition from narrow, task-specific artificial intelligence models in PET/CT toward the application of pretrained, multimodal foundation models. The authors proposed the MOSAIC-PET conceptual framework, outlining six key requirements for deployable systems: preservation of quantitative molecular measurements, robust localization of pathologic changes, image-to-text grounding, adaptability to shifting clinical conditions, seamless clinical workflow integration, and the assurance of algorithmic auditability.
Potential impact
The framework offers clinical and academic teams a way to assess AI solutions beyond accuracy metrics, including how they could fit into clinical work.
Readiness for practice
The proposed framework is strictly conceptual and author-driven. It has not undergone formal validation or Delphi consensus, and it does not represent an official certification system or a clinical scoring tool.
Limitations
Broad real-world clinical utility and the cross-tracer generalization capabilities of the models remain unproven.
Where the field is heading
Together, these publications point toward the integration of hybrid and multimodal approaches, alongside the deep formalization of data interpretation across all stages of cancer care. In clinical diagnostics, there is a clear shift toward deploying molecular imaging at earlier diagnostic stages (prior to invasive procedures) and an effort to combine it with anatomical imaging to optimize patient management strategies. Concurrently, the rigorous evaluation of clinical outcomes underscores the critical importance of distinguishing surrogate endpoints from primary endpoints, while requiring validation of the benefits of imaging-directed interventions in large-scale phase III trials. In parallel, the development of image analysis methods is moving away from narrow, task-specific machine learning models toward comprehensive multimodal systems and standardized reporting protocols. This evolution necessitates auditability, robust interobserver reproducibility, and the confirmation of clinical validity beyond formal academic accuracy metrics.
Selected and reviewed by Dr Konstantin Kenigsberg.